Rated Voltage: 0.6/1kV
Conductor: Cu-conductor
No. Of Cores: 4 Core
Fire Barrier: Mica-tape
Insulation: XLPE
Sheath: LZSH
High Light:

lshf cable

,

lszh power cables

,

4 Core Fire Resistant Cable

Basic Infomation
Place of Origin: Mainland, China
Brand Name: Chengtiantai Cable
Certification: CB, CE
Model Number: WDZ-YJV
Payment & Shipping Terms
Packaging Details: Steel Wooden Drum
Delivery Time: 15 working days
Payment Terms: L/C, T/T
Product Description

Fire resistant cable 4 core 0.6/1 kV Cu-conductor, Mica-tape, XLPE Insulated, LSZH sheathed

 

Fire resistant cable Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Fire resistant cable Construction

1. Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

 

Fire resistant cable Physical and Electrical Characteristics:

 

No.cores x
cross-sec.

Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

mm

mm

mm

kg / km

A

A

Ω/km

4×4

1.0

1.8

18.2

529

30

37

4.61

4×6

1.0

1.8

19.3

641

38

46

3.08

4×10

1.0

1.8

22.5

905

53

64

1.83

4×16

1.0

1.8

25.0

1218

71

83

1.15

4×25

1.2

1.8

29.2

1690

94

108

0.73

4×35

1.2

1.9

33.5

2479

117

132

0.52

4×50

1.4

2.0

34.3

2963

140

157

0.39

4×70

1.4

2.2

37.8

3831

178

196

0.27

4×95

1.6

2.4

43.1

5032

219

234

0.19

4×120

1.6

2.5

46.3

6105

255

268

0.15

4×150

1.8

2.6

51.0

7475

294

301

0.12

4×185

2.0

2.8

56.2

9070

333

338

0.10

4×240

2.2

3.0

61.3

11664

397

393

0.08

4×300

2.4

3.2

69.3

15018

464

448

0.06

 

 

INSTALLATION METHOD DETAILS

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 0

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 1

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 2

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 3

A1 – Thermally insolated wall (Single-core)

A2 – Thermally insolated wall (multi-core)

B1 – Apparent electroduct (Single-core)

B2 – Apparent electroduct (multi-core)

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 4

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 5

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 6

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 7

B1 – Electroduct in brickwork (Single-core)

 

B1 – Electroduct in brickwork (multi-core)

 

C – On the wall

 

 C – On the ceiling

 

 

 

 

 

 

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 8

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 9

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 10

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 11

C – Non-perforated tray

 

F – Perforated tray (Single-core)

 

F – Perforated tray (multi-core)

 

F –Suspended (Single-core)

 

 

 

 

 

 

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 12

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 13

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 14

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 15

E – Suspended (multi-core)

 

B2 – Construction space

 

B2 – Construction space

 

B1 – Electroduct (Single-core)

 

 

 

 

 

 

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 16

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 17

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 18

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 19

B2 – Electroduct (Multi-core)

 

B2 – Closed raceway embedded in floor (multi-core)

 

B2 – Closed raceway embedded in floor (multi-core)

 

B1 – Ventilated raceway embedded in floor

 

 

 

 

 

 

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 20

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 21

 

 

 

 

C – Embedded in the brickwork

 

D – Buried in additional mechanical protection

 

 

 

 

 

 

Fire resistant cable Drum Data

 

CABLE DRUMS

D1=Flange Diameter(mm)

W=Useful Width (mm)

D2=Barrel Diameter(mm)

Low Voltage Power Cable 0.6/1 kV 3+2 Core XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502

1000

700

500

1100

700

550

1200

700

600

1400

750

710

1600

900

900

1800

1120

1000

2400

1150

1300

 

 

  RECOMMENDED ORDERING PARAMETERS

  CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

 

 

  WARRANTY

 

 

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

 

 
Recommended Products
Get in touch with us
Contact Person : Annie Chen
Tel : +8613670012325
Fax : 86-755-29886488
Characters Remaining(20/3000)